What is the remaining status of adaptive servo-ventilation? The results of a real-life multicenter study (OTRLASV-study). Adaptive servo-ventilation in real-life conditions

Redolfi S;
2019-01-01

Abstract

Backgrounds: As a consequence of the increased mortality observed in the SERVE-HF study, many questions concerning the safety and rational use of ASV in other indications emerged. The aim of this study was to describe the clinical characteristics of ASV-treated patients in real-life conditions. Methods: The OTRLASV-study is a prospective, 5-centre study including patients who underwent ASV-treatment for at least 1 year. Patients were consecutively included in the study during the annual visit imposed for ASV- reimbursement renewal. Results: 177/214 patients were analysed (87.57% male) with a median (IQ25–75) age of 71 (65–77) years, an ASV- treatment duration of 2.88 (1.76–4.96) years, an ASV-usage of 6.52 (5.13–7.65) hours/day, and 54.8% were previously treated via continuous positive airway pressure (CPAP). The median Epworth Scale Score decreased from 10 (6–13.5) to 6 (3–9) (p < 0.001) with ASV-therapy, the apnea-hypopnea-index decreased from 50 (38–62)/h to a residual device index of 1.9 (0.7–3.8)/h (p < 0.001). The majority of patients were classified in a Central-Sleep-Apnea group (CSA; 59.3%), whereas the remaining are divided into an Obstructive-Sleep-Apnea group (OSA; 20.3%) and a Treatment-Emergent-Central-Sleep-Apnea group (TECSA; 20.3%). The Left Ventricular Ejection Fraction (LVEF) was > 45% in 92.7% of patients. Associated comorbidities/etiologies were cardiac in nature for 75.7% of patients (neurological for 12.4%, renal for 4.5%, opioid-treatment for 3.4%). 9.6% had idiopathic central-sleep-apnea. 6.2% of the patients were hospitalized the year preceding the study for cardiological reasons. In the 6 months preceding inclusion, night monitoring (i.e. polygraphy or oximetry during ASV usage) was performed in 34.4% of patients, 25.9% of whom required a subsequent setting change. According to multivariable, logistic regression, the variables that were independently associated with poor adherence (ASV-usage ≤4 h in duration) were TECSA group versus CSA group (p = 0.010), a higher Epworth score (p = 0.019) and lack of a night monitoring in the last 6 months (p < 0.05). Conclusions: In real-life conditions, ASV-treatment is often associated with high cardiac comorbidities and high compliance. Future research should assess how regular night monitoring may optimize devices settings and patient management.
2019
Adaptive servo-ventilation; Central sleep apnea; Chronic heart failure; CPAP; Obstructive sleep apnea; Treatment emergent central sleep apnea; Sleep-disordered breathing
File in questo prodotto:
File Dimensione Formato  
33.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 924.48 kB
Formato Adobe PDF
924.48 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Questionario e social

Condividi su:
Impostazioni cookie