Impact of rooftop stack configuration on 2D street canyon air quality

Badas, M G;Garau, M;Seoni, A;Ferrari, S;Querzoli, G
2018-01-01

Abstract

. We experimentally investigated the impact of rooftop stack position on the pollutant entrapment within 2D street canyon configurations. Analyses were performed in a water channel loop system by using the image analysis techniques: FTV (Feature Tracking Velocimetry) and LIF (Light Induced Fluorescein) respectively for measuring velocity and concentration. The set-up consists in an array of 20 identical buildings with aspect ratio equal to one ( = /, where is the height of the eaves and is the building width), mimicking an idealized 2D urban canopy. They were equally spaced with a unitary canyon aspect ratio (defined as = /; where is the distance between buildings facades), and varied in shape by using flat and gable roofs with pitch = 45°, with different chimney positions and heights, for a total number of 9 investigated configurations. Results demonstrate that the presence of gable roof significantly varies the flow in the shear layer, which, in combination with different chimney position and height, lead to not trivial effects on pollutants dispersion.
2018
Inglese
1110
012003
12
Esperti anonimi
internazionale
scientifica
street canyon; rooftop stack; image analysis
no
Badas, M G; Garau, M; Seoni, A; Ferrari, S; Querzoli, G
1.1 Articolo in rivista
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
5
open
File in questo prodotto:
File Dimensione Formato  
Badas_2018_J._Phys.__Conf._Ser._1110_012003.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Questionario e social

Condividi su:
Impostazioni cookie