Abstract

Large-area CdTe single-photon-counting detectors are becoming more and more attractive in view of low-dose imaging applications due to their high efficiency, low intrinsic noise and absence of a scintillating screen which affects spatial resolution. At present, however, since the dimensions of a single sensor are small (typically a few cm2), multi-module architectures are needed to obtain a large field of view. This requires coping with inter-module gaps and with close-to-edge pixels, which generally show a non-optimal behavior. Moreover, high-Z detectors often show gain variations in time due to charge trapping: this effect is detrimental especially in computed tomography (CT) applications where a single tomographic image requires hundreds of projections continuously acquired in several seconds. This work has been carried out at the SYRMEP beamline of the Elettra synchrotron radiation facility (Trieste, Italy), in the framework of the SYRMA-3D project, which aims to perform the world's first breast-CT clinical study with synchrotron radiation. An ad hoc data pre-processing procedure has been developed for the PIXIRAD-8 CdTe single-photon-counting detector, comprising an array of eight 30.7 mm × 24.8 mm modules tiling a 246 mm × 25 mm sensitive area, which covers the full synchrotron radiation beam. The procedure consists of five building blocks, namely dynamic flat-fielding, gap seaming, dynamic ring removal, projection despeckling and around-gap equalization. Each block is discussed and compared, when existing, with conventional approaches. The effectiveness of the pre-processing is demonstrated for phase-contrast CT images of a human breast specimen. The dynamic nature of the proposed procedure, which provides corrections dependent upon the projection index, allows the effective removal of time-dependent artifacts, preserving the main image features including phase effects.
2018
Inglese
25
4
1068
1077
10
Esperti anonimi
internazionale
scientifica
Single-photon counting; CdTe; Pre-processing; Dynamic correction; Breast-CT
no
Brombal, Luca; Donato, Sandro; Brun, Francesco; Delogu, Pasquale; Fanti, Viviana; Oliva, Piernicola; Rigon, Luigi; Di Trapani, Vittorio; Longo, Renata ...espandi
1.1 Articolo in rivista
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
10
partially_open
File in questo prodotto:
File Dimensione Formato  
Brombal_et_al-2018-Journal_of_Synchrotron_Radiation-2.pdf

Solo gestori archivio

Tipologia: versione post-print
Dimensione 5.95 MB
Formato Adobe PDF
5.95 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
article_JSR_LB.pdf

accesso aperto

Tipologia: versione pre-print
Dimensione 8.84 MB
Formato Adobe PDF
8.84 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Questionario e social

Condividi su:
Impostazioni cookie