Semiautomated and automated algorithms for analysis of the carotid artery wall on computed tomography and sonography: a correlation study.

SABA, LUCA;SANFILIPPO, ROBERTO;
2013-01-01

Abstract

OBJECTIVES: The purpose of this study was to compare automated and semiautomated algorithms for analysis of carotid artery wall thickness and intima-media thickness on multidetector row computed tomographic (CT) angiography and sonography, respectively, and to study the correlation between them. METHODS: Twenty consecutive patients underwent multidetector row CT angiographic and sonographic analysis of carotid arteries (mean age, 66 years; age range, 59-79 years). The intima-media thickness of the 40 carotid arteries was measured with novel and dedicated automated software analysis and by 4 observers who manually calculated the intima-media thickness. The carotid artery wall thickness was automatically estimated by using a specific algorithm and was also semiautomatically quantified. The correlation between groups was calculated by using the Pearson ρ statistic, and scatterplots were calculated. We evaluated intermethod agreement using Bland-Altman analysis. RESULTS: By comparing automated carotid artery wall thickness, automated intima-media thickness, semiautomated carotid artery wall thickness, and semiautomated intima-media thickness analyses, a statistically significant association was found, with the highest values obtained for the association between semiautomated and automated intima-media thickness analyses(Pearson ρ = 0.9; 95% confidence interval, 0.82-0.95; P = 0.0001). The lowest values were obtained for the association between semiautomated intima-media thickness and automated carotid artery wall thickness analyses (Pearson ρ = 0.44; 95% confidence interval, 0.15-0.66; P = 0.0047). In the Bland-Altman analysis, the better results were obtained by comparing the semiautomated and automated algorithms for the study of intima-media thickness, with an interval of -16.1% to +43.6%. CONCLUSIONS: The results of this preliminary study showed that carotid artery wall thickness and intima-media thickness can be studied with automated software, although the CT analysis needs to be further improved.
2013
Inglese
32
4
665
674
10
https://onlinelibrary.wiley.com/doi/full/10.7863/jum.2013.32.4.665?sid=nlm:pubmed
Esperti anonimi
internazionale
scientifica
carotid wall; computed tomography; sonography; algorithms
Saba, Luca; Tallapally, N; Gao, H; Molinari, F; Anzidei, M; Piga, M; Sanfilippo, Roberto; Suri, J. S.
1.1 Articolo in rivista
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
8
reserved
Files in This Item:
File Size Format  
2013 - Semiautomated and automated algorithms.pdf

Solo gestori archivio

Description: Articolo principale
Type: versione editoriale
Size 1.48 MB
Format Adobe PDF
1.48 MB Adobe PDF & nbsp; View / Open   Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Questionnaire and social

Share on:
Impostazioni cookie