Tools for Image Analysis and First Wall Protection at W7-X

Pisano F.;Cannas B.;Fanni A.;Sias G.;
2020-01-01

Abstract

The Wendelstein 7-X (W7-X) is the most advanced operating stellarator in fusion research. The monitoring and control of the heat loads on the plasma-facing components (PFCs) will be critical during the next operation phase in which the ten water-cooled divertors will have to withstand heat loads of the order of 10 MW/m2. This paper gives an overview of the image analysis tools for camera spatial calibration and scene modeling that are an essential part of the real-time PFC protection system currently under development at the W7-X. Some applications of these tools are also provided, specifically for the strike-line characterization.
2020
2020
Inglese
76
8
933
941
9
Esperti anonimi
internazionale
scientifica
Image processing; plasma-facing components; thermography
Goal 7: Affordable and clean energy
Pisano, F.; Cannas, B.; Fanni, A.; Sias, G.; Jakubowski, M. W.; Drewelow, P.; Niemann, H.; Puig Sitjes, A.; Gao, Y.; Moncada, V.; Wurden, G.