Interoperability of phasor measurement units under voltage unbalance conditions

Castello, P.;Muscas, C.;Pegoraro, P. A.;
2017-01-01

Abstract

The Phasor Measurement Unit (PMU) is a modern instrument that measures magnitude, phase angle, frequency and rate of change of frequency (ROCOF) from voltage and current signals in electric networks. It is designed to be used in the monitoring and control of electric transmission systems. For each measurement, the PMU assigns a timestamp from an accurate time source; in this way, it is possible to correlate in a common time axis all the measurements collected from different points of the electrical grid. Nowadays, the PMU is a key element of modern Wide Area Measurement Systems (WAMSs) and the number of devices installed in the field is increasing. To guarantee the interoperability of commercial PMUs from different vendors and models, the synchrophasor standard IEEE C37.118.1-2011 (along with its amendment and its predecessors) provides the tests and limits to verify compliance under different conditions. However, the standard does not cover all the conditions that might be encountered in the electric grid. In this work, in the context of a partnership between Terna and the University of Cagliari, the behavior of three different commercial PMUs compliant with three different versions of the synchrophasor standard will be analyzed to study the interoperability of PMUs under the unconventional (i.e. not considered as a mandatory test in current standards) condition of voltage unbalance.
2017
Inglese
2017 AEIT International Annual Conference: Infrastructures for Energy and ICT: Opportunities for Fostering Innovation
978-8-8872-3737-5
IEEE (Institute of Electrical and Electronics Engineers)
1
6
6
2017 AEIT International Annual Conference
Esperti anonimi
20-22 September 2017
Cagliari, Italy
internazionale
scientifica
Current measurement; Frequency measurement; Interoperability; Monitoring; Phasor measurement units; Standards; Voltage measurement; Interoperability; Phasor Measurement Unit (PMU); Power Quality; Trasmission System; Unbalance Conditions; Wide Area Measurement System (WAMS)
no
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
Castello, P.; Muscas, C.; Pegoraro, P. A.; Guida, G.; Giannuzzi, G. M.; Pau, P.
273
6
4.1 Contributo in Atti di convegno
reserved
info:eu-repo/semantics/conferencePaper
Files in This Item:
File Size Format  
08240491_AEIT.pdf

Solo gestori archivio

Description: File from proceedings
Type: versione editoriale
Size 410.72 kB
Format Adobe PDF
410.72 kB Adobe PDF & nbsp; View / Open   Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Questionnaire and social

Share on:
Impostazioni cookie