This paper deals with the structural assessment of the main cupola of the 17th century Church Beata Vergine di Monserrato, in the center of Barisardo, eastern coast of Sardinia (Italy). In 2004 the whole structure was subjected to a conservative intervention, including a partial consolidation of the cupola, affected by an extended state of damage; nevertheless, soon after the dome required some newer interventions and doubts rose upon its stability. In this paper the safety level of the dome and an interpretation of the damages have been tackled by means of a two-way approach: Finite Element modelling and Limit Analysis calculations. The results of the two approaches have been compared and discussed leading to a reinforcing proposal by means of CFRP sheets glued on the external surface of the masonry structure.
2010
Advances and Trends in Structural Engineering, Mechanics and Computation. PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION
978-0-415-58472-2
CRC Press – Taylor and Francis Group
LONDON
338
http://www.crcnetbase.com/doi/pdfplusdirect/10.1201/b10557-1
4th International Conference on Structural Engineering, Mechanics and Computation (SEMC 2010)
September 6-8, 2010
Cape Town, South Africa
internazionale
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
Meloni, Daniel; Concu, Giovanna; DE NICOLO, Barbara; Valdes, Monica
273
4
4.1 Contributo in Atti di convegno
none
info:eu-repo/semantics/conferenceObject
Files in This Item:
There are no files associated with this item.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Questionnaire and social

Share on:
Impostazioni cookie